AIR CONDITIONING SYSTEM IG Power Source Circuit

DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the power switch is on (IG).

The power is used for operating the air conditioning amplifier assembly, servo motors, etc.

WIRING DIAGRAM

A01MFR4E01
*a IG1 NO. 4 Relay
*b Air Conditioning Amplifier Assembly

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - POWER SOURCE CIRCUIT)


    1. A01MH9JC23
      *a

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      G43-1 (IG+) - Body ground Power switch off Below 1 V
      G43-1 (IG+) - Body ground Power switch on (IG) 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G43-14 (GND) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG