| DTC Code | DTC Name |
|---|---|
| B14A9 | Glass Surroundings Temperature Sensor Circuit |
DESCRIPTION
The air conditioning amplifier assembly detects the temperature of the area near the windshield glass using this circuit. The air conditioning amplifier assembly applies voltage to the air conditioning thermistor assembly (glass surroundings temperature sensor). As the temperature of the area near the windshield glass rises, the resistance decreases. The air conditioning amplifier assembly detects the change in resistance as the windshield glass surroundings temperature changes.
The glass surroundings temperature sensor is integrated with the air conditioning thermistor assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14A9 | Glass Surroundings Temperature Sensor Circuit | Any of the following conditions is met:
|
|
Memorized (4 seconds or more) |
Tech Tips
The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Power switch on (IG) | ○ | ○ |
| Malfunction Status | Open in glass surroundings temperature sensor circuit | ○ | - |
| Short in glass surroundings temperature sensor circuit | - | ○ | |
| Detection Time | 4 seconds or more | 4 seconds or more | |
| Number of Trips | 1 trip | 1 trip | |
Tech Tips
DTC will be output when conditions for either of the patterns in the table above are met.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Tech Tips
The air conditioning thermistor assembly must be replaced if the glass surroundings temperature sensor is malfunctioning.
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Glass Surroundings Temperature | Glass surroundings temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual glass surroundings temperature is displayed | - |
| Tester Display |
|---|
| Glass Surroundings Temperature |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| A |
|
INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS SURROUNDINGS TEMPERATURE SENSOR)
Remove the air conditioning thermistor assembly (glass surroundings temperature sensor).
Inspect the air conditioning thermistor assembly (glass surroundings temperature sensor).
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS SURROUNDINGS TEMPERATURE SENSOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS SURROUNDINGS TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the W11 air conditioning thermistor assembly (glass surroundings temperature sensor) connector.
Disconnect the G43 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |