DESCRIPTION
In this circuit, the combination meter assembly receives FC Stack coolant temperature signals from the FC control ECU via the CAN communication system. The combination meter assembly displays the FC Stack coolant temperature that is calculated based on the data received from the FC control ECU.
WIRING DIAGRAM
| *1 | FC control ECU |
| *2 | Combination Meter Assembly |
| *3 | CAN Communication Line |
CAUTION / NOTICE / HINT
Note
When replacing the combination meter assembly, make sure to replace it with a new one.
If there is an open or short in the FC coolant temperature sensor circuit, the FC control ECU stores DTCs. Troubleshoot the FC system.
PROCEDURE
CHECK FOR DTC (CAN COMMUNICATION SYSTEM)
Check for DTCs.
for LHD: Click here
for RHD: Click here
| OK |
|---|
| No DTCs are output. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
GO TO CAN COMMUNICATION SYSTEM Click here |
| C |
|
GO TO CAN COMMUNICATION SYSTEM Click here |
| A |
|
CHECK FOR DTC (FC SYSTEM)
Check for DTCs.
| OK |
|---|
| No DTCs are output. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO FC CONTROL SYSTEM Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS (INDICAT. LAMP COOLANT HOT)
Using the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Indicat. Lamp Coolant Hot | Water temperature hot warning light | OFF or ON | - |
| Tester Display |
|---|
| Indicat. Lamp Coolant Hot |
| OK |
|---|
| Value selected during Active Test is displayed. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE COMBINATION METER ASSEMBLY Click here |
| OK |
|
READ VALUE USING GTS (FC STACK COOLANT TEMPERATURE (FC OUTLET), FC COOLANT TEMPERATURE)
Using the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Stack Coolant Temperature (Radiator Outlet) | FC coolant temperature | Min.: -40°C (-40°F), Max: 215°C (419°F) | 50 to 85°C (122 to 185°F): After warming up | - |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Coolant Temperature | FC Stack coolant temperature | Min.: 0°C (0°F), Max.: 127.5°C (261.5°F) | 50 to 85°C (122 to 185°F): After warming up | - |
| Tester Display |
|---|
| FC Stack Coolant Temperature (Radiator Outlet) |
| Tester Display |
|---|
| FC Coolant Temperature |
Tech Tips
When the Data List values of the ECUs match, an internal malfunction of the FC control ECU is suspected.
When the Data List values of the ECUs do not match, a signal output error of the FC control ECU or an internal malfunction of the combination meter assembly is suspected.
| OK |
|---|
| The Data List values of the ECUs do not match. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE FC CONTROL ECU Click here |
| OK |
|
CHECK COMBINATION METER ASSEMBLY
Replace the combination meter assembly.
Check that the operation of the water temperature warning returns to normal.
| OK |
|---|
| The operation of the water temperature warning returns to normal. |
| Result | |||
|---|---|---|---|
|
| OK |
|
END (COMBINATION METER ASSEMBLY IS DEFECTIVE) |
| NG |
|
REPLACE FC CONTROL ECU Click here |