LIGHTING SYSTEM Illumination Circuit

DESCRIPTION

The main body ECU (multiplex network body ECU) controls the front door inside handle illumination lights.

WIRING DIAGRAM

A01MGXNE03

CAUTION / NOTICE / HINT

Note


  • Inspect the lights for circuits related to this system before performing the following procedure.

  • Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.

PROCEDURE


  1. PERFORM ACTIVE TEST USING GTS (FR FOOT LIGHT)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Active Test.

    5. Perform the Active Test according to the display on the GTS.


      Body Electrical > Main Body > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Fr Foot Light No. 1 interior illumination light assembly ON or OFF

      Precondition for performing the Active Test to turn lights on and off:

      Power switch is turned off just before performing the Active Test.


      Body Electrical > Main Body > Active Test
      Tester Display
      Fr Foot Light
      OK
      No. 1 interior illumination light assembly comes on.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)


    1. Disconnect the 4F instrument panel junction block assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      4F-1 - Body ground Always 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly.

      for LHD: Click here

      for RHD: Click here

    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

      for LHD: Click here

      for RHD: Click here

    3. Measure the resistance according to the value(s) in the table below.

      A01MJL3C02
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      4F-1 - 4D-27 Always Below 1 Ω
      4F-1 - 4B-15 Always Below 1 Ω
      4B-22 - MB-26 (FSPT) Always Below 1 Ω
      4D-26 - MB-26 (FSPT) Always Below 1 Ω
      Result
      Result Proceed to
      OK (for LHD) A
      OK (for RHD) B
      NG (for LHD) C
      NG (for RHD) D

    A
    B
    C
    D