ULTRASONIC SENSOR(for Rear Side) INSPECTION

PROCEDURE


  1. INSPECT NO. 2 ULTRASONIC SENSOR


    1. A01MI5VC10
      *a

      Component without harness connected

      (No. 2 Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (E) - 2 (S) Always 20 to 40 kΩ

      • If the result is not as specified, replace the No. 2 ultrasonic sensor.