TRANSMISSION SHIFT MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT P POSITION SWITCH (TRANSMISSION SHIFT MAIN SWITCH)


    1. Check the resistance.


      1. A01MHH2C01
        *a

        Component without harness connected

        (P Position Switch (Transmission Shift Main Switch))

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        4 (S) - 2 (E) Switch on 646 to 714 Ω
        Switch off 4351 to 4809 Ω

        If the result is not as specified, replace the integration control and panel assembly.

    2. Check the Illumination.


      1. Apply auxiliary battery voltage to the P position switch and check that it illuminates.

        OK
        Auxiliary Battery Connection Specified Condition

        Auxiliary battery positive (+) → 6 (IND+)

        Auxiliary battery negative (-) → 7 (IND-)

        Illuminates

        Auxiliary battery positive (+) → 5 (ILL+)

        Auxiliary battery negative (-) → 3 (ILL-)

        Illuminates

        If the result is not as specified, replace the integration control and panel assembly.