PROCEDURE
INSPECT FC COOLING WATER TEMPERATURE CONTROL VALVE
Check the resistance.
| *a | Component without harness connected (FC Cooling Water Temperature Control Valve) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (B1) - 6 (WRA2) | 20°C (68°F) | 18 to 22 Ω |
| 5 (B1) - 4 (WRA1) | 20°C (68°F) | 18 to 22 Ω |
| 2 (B2) - 3 (WRB2) | 20°C (68°F) | 18 to 22 Ω |
| 2 (B2) - 1 (WRB1) | 20°C (68°F) | 18 to 22 Ω |
If the result is not as specified, replace the FC cooling water temperature control valve.