DATA LIST
Note
Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / FCDC / Data List.
Check the results by referring to the following table.
Tech Tips
When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Voltage before Boosting | FC converter input voltage sensor value (voltage before boosting) | - | 0 to 370 V | Value of the FVL sensor located inside the FC converter |
| FC Voltage after Boosting | FC converter output voltage sensor value (voltage after boosting) | - | 0 to 650 V | Value of the FVH sensor located inside the FC converter |
| FC Current | FC current sensor value | - | 0 to 500 A | - |
| Ignition Signal | IG2 terminal condition | ON/OFF | - | - |
| Inverter Shutdown Request | Inverter shutdown signal status | ON/OFF | - | - |
| FC Voltage Status | FC stack generated voltage condition | ON/OFF | - | - |
| FC Current Status | FC stack generated current condition | ON/OFF | - | - |
| FC Converter Voltage Status | FC converter output voltage condition | ON/OFF | - | - |
| Reactor Temperature | V phase reactor temperature sensor value | -40 to 215°C (-40 to 419°F) | 15 to 138°C (59 to 280°F) | - |
| FC Relay (+) AD Value | FC relay (FCB) positive (+) terminal CPU input AD value | 0 to 4.98 V | - | - |
| FC Relay (-) AD Value | FC relay (FCG) positive (-) terminal CPU input AD value | 0 to 4.98 V | - | - |
| AC Impedance Relative Value | Displays control information for AC impedance | 0 to 65535 s | - | - |
| Capacitor Estimated Temperature | Estimated capacitor temperature | -40 to 215°C (-40 to 419°F) | - | - |
| Reactor Total Current | Total current value of reactors | 0 to 655.35 A | - | - |
| Reactor Temperature Estimate Degree | Estimated temperature of V phase reactor | -40 to 215°C (-40 to 419°F) | 15 to 138°C (59 to 280°F) | - |
| Target FC Output Power | Command value for FC system power output | - | 0 to 110 kW | - |
| Target FC Current | Command value for FC system current output | - | 0 to 500 A | - |
| FC Converter Estimated Water Temperature (U/V/W/X Total) | Estimated temperatures of phases U, V, W, and X are indicated as a total temperature value | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| FC Relay (+) | FC relay (FCB) status | ON/OFF | - | - |
| FC Relay (-) | FC relay (FCG) status | ON/OFF | - | - |
| FVH (FC Converter Boosted Voltage) Over Voltage Judgment | FVH (FC Converter Output Voltage) over voltage fail signal | ON/OFF | - | - |
| FVL (FC Converter Before Boosting Voltage) Low Voltage Judgment | FVL (FC Converter Input Voltage) low voltage fail signal | ON/OFF | - | - |
| FC Converter Control | Control data for FFCV | ON/OFF | - | - |
| FVL (FC Converter Before Boosting Voltage) IPM Low Voltage Signal | Data which is used for determining whether there is a malfunction in FLVL (Low voltage before boosting) | ON/OFF | - | - |
| FVH (FC Converter Boosted Voltage) IPM Over Voltage Signal | Data which is used for determining whether there is a malfunction in FOVH (Overvoltage after boosting) | ON/OFF | - | - |
| FLVL-RG Signal Status | Control data for FLVL-RG signal | ON/OFF | - | - |
| Fail Safe Status | Control data for fail-safe control | ON/OFF | - | - |
| Target FC Voltage | Command value for FC voltage | - | 0 to 370 V | - |
| Smoothed Value of FC Voltage | FC voltage sensor value | - | 0 to 370 V | - |
| FC Converter Output Voltage | FC converter output voltage sensor value | - | 200 to 650 V | Voltages of 200V or lower, or 650V or higher may be indicated due to sensor offset even when no malfunction is present. |
| FC Output Power | FC output power value | - | 0 to 110 kW | - |
| 26V Voltage AD Value | +26 V Power source CPU input AD value | 0 to 4.98 V | - | - |
| -5 Voltage AD Value | -5 V Power source CPU input AD value | 0 to 4.98 V | - | - |
| 5 Voltage AD Value | 5 V Power source CPU input AD value | 0 to 4.98 V | - | - |
| U Phase IGBT Temperature | U phase IGBT temperature sensor value | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| U Phase IGBT Temperature AD Value | U phase IGBT temperature sensor CPU input AD value | 0 to 4.99 V | - | - |
| U Phase IGBT Request Duty Ratio | Command value for U phase S1 Duty | - | 0 to 98% | - |
| U Phase Reactor Current | U phase reactor current sensor value | - | 0 to 125 A | - |
| U Phase Reactor Current AD Value | U phase reactor sensor CPU input AD value | 0 to 4.99 V | - | - |
| U Phase FC Converter Estimated Water Temperature | Estimated coolant temperature of U phase converter | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| U Phase IPM Fail Signal Judgment (Over Heat) | Data which is used for determining whether there is a malfunction in U phase IPM (Overheat) | ON/OFF | - | - |
| U Phase IPM Fail Judgment (Over Current) | Data which is used for determining whether there is a malfunction in U phase IPM (Overcurrent) | ON/OFF | - | - |
| U Phase IPM Fail Signal | U phase IPM fail signal | ON/OFF | - | - |
| U Phase Fail Safe Status | Control data for U phase fail-safe control | ON/OFF | - | - |
| U Phase FC Converter Shutdown Request | Shutdown command value for U phase converter | ON/OFF | - | - |
| U Phase Reactor Current Status | Command value for U phase reactor current | ON/OFF | - | - |
| U Phase Element Estimated Temperature | Estimated temperature of U phase element | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| V Phase IGBT Temperature | V phase IGBT temperature sensor value | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | 15 to 117°C |
| V Phase IGBT Temperature AD Value | V phase IGBT temperature sensor CPU input AD value | 0 to 4.99 V | - | - |
| V Phase IGBT Request Duty Ratio | Command value for V phase S1 Duty | - | 0 to 98% | - |
| V Phase Reactor Current | V phase reactor current sensor value | - | 0 to 125 A | - |
| V Phase Reactor Current AD Value | V phase reactor sensor CPU input AD value | 0 to 4.99 V | - | - |
| V Phase Reactor Temperature AD Value | V phase reactor temperature sensor CPU input AD value | 0 to 4.99 V | - | - |
| V Phase FC Converter Estimated Water Temperature | Estimated coolant temperature of U phase converter | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| V Phase IPM Fail Signal Judgment (Over Heat) | Data which is used for determining whether there is a malfunction in V phase IPM (Overheat) | ON/OFF | - | - |
| V Phase IPM Fail Judgment (Over Current) | Data which is used for determining whether there is a malfunction in V phase IPM (Overcurrent) | ON/OFF | - | - |
| V Phase IPM Fail Signal | V phase IPM fail signal | ON/OFF | - | - |
| V Phase Fail Safe Status | Control data for V phase fail-safe control | ON/OFF | - | - |
| V Phase FC Converter Shutdown Request | Shutdown command value for V phase converter | ON/OFF | - | - |
| V Phase Reactor Current Status | Command value for V phase reactor current | ON/OFF | - | - |
| V Phase Element Estimated Temperature | Estimated temperature of V phase element | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| W Phase IGBT Temperature | W phase IGBT temperature sensor value | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| W Phase IGBT Temperature AD Value | W phase IGBT temperature sensor CPU input AD value | 0 to 4.99 V | - | - |
| W Phase IGBT Request Duty Ratio | Command value for W phase S1 Duty | - | 0 to 98% | - |
| W Phase Reactor Current | W phase reactor current sensor value | - | 0 to 125 A | - |
| W Phase Reactor Current AD Value | W phase reactor sensor CPU input AD value | 0 to 4.99 V | - | - |
| W Phase FC Converter Estimated Water Temperature | Estimated coolant temperature of W phase converter | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| W Phase IPM Fail Signal Judgment (Over Heat) | Data which is used for determining whether there is a malfunction in W phase IPM (Overheat) | ON/OFF | - | - |
| W Phase IPM Fail Judgment (Over Current) | Data which is used for determining whether there is a malfunction in W phase IPM (Overcurrent) | ON/OFF | - | - |
| W Phase IPM Fail Signal | W phase IPM fail signal | ON/OFF | - | - |
| W Phase Fail Safe Status | Control data for W phase fail-safe control | ON/OFF | - | - |
| W Phase FC Converter Shutdown Request | Shutdown command value for W phase converter | ON/OFF | - | - |
| W Phase Reactor Current Status | Command value for W phase reactor current | ON/OFF | - | - |
| W Phase Element Estimated Temperature | Estimated temperature of W phase element | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| X Phase IGBT Temperature | X phase IGBT temperature sensor value | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| X Phase IGBT Temperature AD Value | X phase IGBT temperature sensor CPU input AD value | 0 to 4.99 V | - | - |
| X Phase IGBT Request Duty Ratio | Command value for X phase S1 Duty | - | 0 to 98% | - |
| X Phase Reactor Current | X phase reactor current sensor value | - | 0 to 125 A | - |
| X Phase Reactor Current AD Value | X phase reactor sensor CPU input AD value | 0 to 4.99 V | - | - |
| X Phase FC Converter Estimated Water Temperature | Estimated coolant temperature of X phase converter | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| X Phase IPM Fail Signal Judgment (Over Heat) | Data which is used for determining whether there is a malfunction in X phase IPM (Overheat) | ON/OFF | - | - |
| X Phase IPM Fail Judgment (Over Current) | Data which is used for determining whether there is a malfunction in X phase IPM (Overcurrent) | ON/OFF | - | - |
| X Phase IPM Fail Signal | X phase IPM fail signal | ON/OFF | - | - |
| X Phase Fail Safe Status | Control data for X phase fail-safe control | ON/OFF | - | - |
| X Phase FC Converter Shutdown Request | Shutdown command value for X phase converter | ON/OFF | - | - |
| X Phase Reactor Current Status | Command value for X phase reactor current | ON/OFF | - | - |
| X Phase Element Estimated Temperature | Estimated temperature of X phase element | -40 to 215°C (-40 to 419°F) | 15 to 117°C (59 to 243°F) | - |
| Battery Voltage | Auxiliary battery voltage | - | 11 to 15.5 V | - |
| Total Distance Traveled | Drive total distance | 0 to 16777215 km (0 to 10425361 mile) | - | - |
| Check Mode | Check Mode | ON or OFF | - | - |