FC CONTROL SYSTEM, Diagnostic DTC:P1DD2-450, P1DD3-450

DTC Code DTC Name
P1DD2-450 Tank Side Hydrogen Detector Circuit Low
P1DD3-450 Tank Side Hydrogen Detector Circuit High

DESCRIPTION

Refer to DTC P1DCC-450.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate
P1DD2-450 Tank Side Hydrogen Detector Circuit Low

FC PWR2 relay is ON and the hydrogen detector (for hydrogen tank side) voltage has remained at less than 0.3 V for 3 seconds.

(1 trip detection logic)


  • Hydrogen detector (for hydrogen tank side)

  • FC control ECU

  • FC PWR2 relay

  • Wire harness or connector

Master Warning Light: Comes on
P1DD3-450 Tank Side Hydrogen Detector Circuit High

FC PWR2 relay is ON and the hydrogen detector (for hydrogen tank side) voltage has remained at more than 4.65 V for 3 seconds.

(1 trip detection logic)


  • Hydrogen detector (for hydrogen tank side)

  • FC control ECU

  • FC PWR2 relay

  • Wire harness or connector

Master Warning Light: Comes on
Detection timing
Vehicle Condition

FC shutdown

(power switch on (IG))

FC startup process FC intermittent operation

FC is generating power

(vehicle is in stationary)

FC is generating power

(vehicle is traveling)

FC shutdown process

Data List

"FC Mode"

FC Shutdown FC Startup Process FC Working FC Shutdown Process

Data List

"FC Intermittent Operation"

OFF ON OFF OFF
DTC Detection -
Related Data List
DTC No. Data List
P1DD2-450 Tank Side Hydrogen Detector Voltage
P1DD3-450

WIRING DIAGRAM

A01MJ10E05

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses of circuits related to this system before performing the following procedure.

  • When the vehicle is parked with the power switch off, if the FC control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the power switch off (not on (IG) or on (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work (If the auxiliary battery voltage is needed to conduct inspection, warm up the FC system beforehand).

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Turn the power switch on (IG) and wait for 30 seconds or more.

PROCEDURE


  1. CHECK DTC OUTPUT


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / FC / Trouble Codes.

    5. Check for DTCs.


      Powertrain > FC > Trouble Codes
      Result
      Result Proceed to
      Any of the following DTCs are also output. A
      P1DD2-450 or P1DD3-450 only is output, or DTCs except the ones in the table below are also output. B
      Malfunction Content Relevant DTC
      Sensor and Actuator Circuit Malfunction P0100-450 Mass Air Flow Circuit
      P1DCC-450 Motor Room Side Hydrogen Detector Circuit Low
      P1DCD-450 Motor Room Side Hydrogen Detector Circuit High
      Communication System Malfunction U1162-450 Lost Communication with Hydrogen Filling System
    6. Turn the power switch off.


    B
    A
  2. CHECK TERMINAL VOLTAGE (POWER SOURCE OF FC PWR2 RELAY)


    1. A01MJVFC01
      *1 Motor Compartment Relay Block
      *2 FC PWR2 Relay Holder

      Remove the FC PWR2 relay from the motor compartment relay block.

    2. Turn the power switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1 (FC PWR2 relay holder) - Body ground Power switch on (IG) 11 to 14 V
    4. Turn the power switch off.

    5. Reinstall the FC PWR2 relay.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT RELAY (FC PWR2)

    Click here

    Result
    Proceed to
    OK
    NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (FC PWR2 RELAY - BODY GROUND)


    1. A01MJVFC01
      *1 Motor Compartment Relay Block
      *2 FC PWR2 Relay Holder

      Remove the FC PWR2 relay from the motor compartment relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (FC PWR2 relay holder) - Body ground Always Below 1 Ω
    3. Reinstall the FC PWR2 relay.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. CHECK TERMINAL VOLTAGE (POWER SOURCE OF FC PWR2 RELAY)


    1. A01MJVFC01
      *1 Motor Compartment Relay Block
      *2 FC PWR2 Relay Holder

      Remove the FC PWR2 relay from the motor compartment relay block.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      5 (FC PWR2 relay holder) - Body ground Power switch off 11 to 14 V
    3. Reinstall the FC PWR2 relay.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  6. CHECK TERMINAL VOLTAGE (POWER SOURCE OF HYDROGEN DETECTOR (FOR HYDROGEN TANK SIDE))


    1. A01MHOR

      Disconnect the hydrogen detector (for hydrogen tank side) connector.

    2. Turn the power switch on (IG).

    3. A01MJFHC08
      *a

      Front view of wire harness connector

      (to Hydrogen Detector (for Hydrogen Tank Side))

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      R5-3 (+B) - Body ground Power switch on (IG) 11 to 14 V
    4. Turn the power switch off.

    5. Reconnect the hydrogen detector (for hydrogen tank side) connector.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (HYDROGEN DETECTOR (FOR HYDROGEN TANK SIDE) - BODY GROUND)


    1. A01MJFHC09
      *a

      Front view of wire harness connector

      (to Hydrogen Detector (for Hydrogen Tank Side))

      Disconnect the hydrogen detector (for hydrogen tank side) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      R5-4 (GND) - Body ground Always Below 1 Ω
    3. Reconnect the hydrogen detector (for hydrogen tank side) connector.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN DETECTOR (FOR HYDROGEN TANK SIDE))


    1. Disconnect the FC control ECU connector.

    2. Disconnect the hydrogen detector (for hydrogen tank side) connector.

    3. A01MISVC02
      *a

      Front view of wire harness connector

      (to Hydrogen Detector (for Hydrogen Tank Side))

      *b

      Front view of wire harness connector

      (to FC Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A47-51 (HDTN) - R5-1 (HDTN) Always Below 1 Ω
      A47-51 (HDTN) or R5-1 (HDTN) - Body ground and other terminals Always 10 kΩ or higher
    4. Reconnect the hydrogen detector (for hydrogen tank side) connector.

    5. Reconnect the FC control ECU connector.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  9. REPLACE HYDROGEN DETECTOR (FOR HYDROGEN TANK SIDE)

    Click here

    Result
    Proceed to
    NEXT

    NEXT
  10. CLEAR DTC


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / FC / Trouble Codes.

    5. Clear the DTCs.


      Powertrain > FC > Clear DTCs
    6. Turn the Power switch off and wait for 3 minutes or more.

      Result
      Proceed to
      NEXT

    NEXT
  11. CHECK DTC OUTPUT


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG) and wait for 30 seconds or more.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / FC / Trouble Codes.

    5. Check for DTCs.


      Powertrain > FC > Trouble Codes
      Result
      Result Proceed to
      DTC P1DD2-450 or P1DD3-450 are output A
      DTCs are not output B
    6. Turn the power switch off.


    A
    B
  12. CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - FC PWR2 RELAY)


    1. Disconnect the FC control ECU connector.

    2. Remove the FC PWR2 relay from the motor compartment relay block.

    3. Measure the resistance according to the value(s) in the table below.

      A01MG5NC05
      *1 Motor Compartment Relay Block *2 FC PWR2 Relay Holder
      *a

      Front view of wire harness connector

      (to FC Control ECU)

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      A48-33 (RLF2) - 1 (FC PWR2 relay holder) Always Below 1 Ω
      A48-33 (RLF2) or 1 (FC PWR2 relay holder) - Body ground and other terminals Always 10 kΩ or higher
    4. Reinstall the FC PWR2 relay.

    5. Reconnect the FC control ECU connector.

      Result
      Proceed to
      OK
      NG

    OK
    NG