FC CONTROL SYSTEM PROBLEM SYMPTOMS TABLE

FC Control System
Symptom Suspected Area Link
H2O indicator light does not illuminate FC Water Release Switch Circuit

Click here

Combination meter assembly

Click here

FC Water Release Switch

Click here

H2O indicator light does not turn off FC Water Release Switch Circuit

Click here

Combination meter assembly

Click here

FC Water Release Switch

Click here

Hesitation and/or poor acceleration

Vehicle Control History

("FC Output Limit" is stored in the memory)

Click here

Power switch does not turn on (READY).*2 Auxiliary Battery (Low voltage)

Click here

Fuel Lid (Open lid) -
Hydrogen (fuel) ran out

Vehicle Control History

("Hydrogen Empty Low Level" is stored in the memory)

Click here

Hydrogen filling stopped

Vehicle Control History

("Hydrogen Filling Abort" is stored in the memory)

Click here

Hydrogen filling continues long If the ambient temperature is high when filling hydrogen, extra time is required to complete it. Also, filling time may vary depending on the hydrogen stations. -
Filling was completed, but the tank is not full Vehicle was refueled at a hydrogen station without communication filling system. -

Hydrogen station factors:


  • Filling pressure decreased

  • Interlocks were actuated

-

Vehicle Control History

("Hydrogen Filling Abort" is stored in the memory)

Click here

Infrared Transmitter Circuit*1

Click here

The fuel lid is actually closed, but the multi-information display shows "Close H2 Filler Door and Restart Your Vehicle" and so READY ON is not possible. Fuel Lid Interlock Circuit

Click here

Combination meter assembly

Click here

After the power switch is turned on (IG or READY), "H2 Filler Door is open. Park Your Vehicle in a Safe Place and Close H2 Filler Door" is displayed on the multi-information display despite the fact that the fuel lid is actually closed. Fuel Lid Interlock Circuit

Click here

Combination meter assembly

Click here