| Symptom | Suspected Area | Link |
|---|---|---|
| "MAINTENANCE REQUIRED FOR HYBRID BATTERY COOLING PARTS AT YOUR DEALER" is displayed on the multi-information display* | 1. Make sure the air intake port is not blocked. | - |
| 2. Make sure there are no gaps between the connecting parts of the ducts. | - | |
| 3. Clean the No. 1 EV battery intake duct (filter) (check for entry of foreign matter). | ||
| 4. Clear the DTCs to reset the learning values even if no DTCs are stored. | ||
| Abnormal sound is heard from the area around the No. 1 EV battery intake duct | 1. Make sure the air intake port is not blocked. | - |
| 2. Make sure there are no gaps between the connecting. | - | |
| 3. Clean the No. 1 EV battery intake duct (filter) (Check for entry of foreign matter) |
Note
*: If a malfunction occurs in the battery cooling blower itself, DTCs P0A82-123, P0A84-123, or P0A85-123 are stored. If only the "MAINTENANCE REQUIRED FOR HYBRID BATTERY COOLING PARTS AT YOUR DEALER" is displayed on the multi-information display, only perform the inspection of the EV battery cooling system intake port, filter and duct as shown above.