AIR CONDITIONING SYSTEM(for Manual Cooler System) TERMINALS OF ECU


  1. AIR CONDITIONING AMPLIFIER ASSEMBLY

    B0027SGN02

    1. Disconnect the G34 air conditioning amplifier assembly connector.

    2. Measure the voltage and resistance according to the value(s) in the table below.

      Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
      G34-7 (IG+) - Body ground G - Body ground Power source (IG) Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V
      G34-11 (GND) - Body ground W-B - Body ground Ground Always Below 1 Ω
    3. Reconnect the G34 air conditioning amplifier assembly connector.

    4. Measure the voltage and resistance according to the value(s) in the table below.

      Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
      G34-2 (AC1) - Body ground GR - Body ground Idle-up request signal
      • Engine running

      • Blower switch: LO

      • Cooler volume switch: Off

      11 to 14 V

      • Engine running

      • Blower switch: LO

      • Cooler volume switch: On

      Below 1 V
      G34-3 (PSW) - Body ground L - Body ground Air conditioner pressure sensor signal
      • Engine running

      • Refrigerant pressure normal

      • Blower switch: LO or higher

      • Cooler volume switch: On

      Below 1 V

      • Engine running

      • Refrigerant pressure abnormal (below 0.176 MPa [1.8 kgf/cm2, 25.5 psi] or higher than 3.025 MPa [30.9 kgf/cm2, 438.6 psi])

      • Blower switch: LO or higher

      • Cooler volume switch: On

      11 to 14 V
      G34-4 (ACT) - Body ground LG - Body ground Magnet clutch on permit signal
      • Engine running

      • Blower switch: LO or higher

      • Cooler volume switch: On (magnet clutch on)

      4.5 to 5.5 V

      • Engine running

      • Blower switch: LO or higher

      • Cooler volume switch: Off or on (magnet clutch off)

      Below 1 V
      G34-5 (SG-2) - Body ground L - Body ground Ground for No. 1 cooler thermistor Always Below 1 Ω
      G34-6 (TE) - Body ground P - Body ground No. 1 cooler thermistor signal Evaporator temperature (ambient): 0°C (32°F) 1.7 to 2.1 V
      Evaporator temperature (ambient): 15°C (59°F) 1.0 to 1.3 V
      Evaporator temperature (ambient): 20°C (68°F) 0.8 to 1.1 V
      Evaporator temperature (ambient): 25°C (77°F) 0.6 to 0.9 V
      Evaporator temperature (ambient): 30°C (86°F) 0.5 to 0.8 V
      G34-10 (MGC) - Body ground V - Body ground Cooler compressor assembly operation signal
      • Engine running

      • Blower switch: LO or higher

      • Cooler volume switch: Off or on (magnet clutch off)

      11 to 14 V

      • Engine running

      • Blower switch set to LO or higher

      • Cooler volume switch: On (magnet clutch on)

      Below 1 V
      G34-12 (B/V) - Body ground Y - Body ground Air conditioning volume switch signal Cooler volume switch: Off 0.0 to 0.4 V
      Cooler volume switch: MAX COOL 1.6 to 2.0 V
  2. ECM