AIR CONDITIONING AMPLIFIER ASSEMBLY
Disconnect the G34 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G34-7 (IG+) - Body ground | G - Body ground | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| G34-11 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the G34 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G34-2 (AC1) - Body ground | GR - Body ground | Idle-up request signal |
|
11 to 14 V |
|
Below 1 V | |||
| G34-3 (PSW) - Body ground | L - Body ground | Air conditioner pressure sensor signal |
|
Below 1 V |
|
11 to 14 V | |||
| G34-4 (ACT) - Body ground | LG - Body ground | Magnet clutch on permit signal |
|
4.5 to 5.5 V |
|
Below 1 V | |||
| G34-5 (SG-2) - Body ground | L - Body ground | Ground for No. 1 cooler thermistor | Always | Below 1 Ω |
| G34-6 (TE) - Body ground | P - Body ground | No. 1 cooler thermistor signal | Evaporator temperature (ambient): 0°C (32°F) | 1.7 to 2.1 V |
| Evaporator temperature (ambient): 15°C (59°F) | 1.0 to 1.3 V | |||
| Evaporator temperature (ambient): 20°C (68°F) | 0.8 to 1.1 V | |||
| Evaporator temperature (ambient): 25°C (77°F) | 0.6 to 0.9 V | |||
| Evaporator temperature (ambient): 30°C (86°F) | 0.5 to 0.8 V | |||
| G34-10 (MGC) - Body ground | V - Body ground | Cooler compressor assembly operation signal |
|
11 to 14 V |
|
Below 1 V | |||
| G34-12 (B/V) - Body ground | Y - Body ground | Air conditioning volume switch signal | Cooler volume switch: Off | 0.0 to 0.4 V |
| Cooler volume switch: MAX COOL | 1.6 to 2.0 V |
ECM