| *A | w/ Rear Face Register | *B | w/ Rear Footwel Register |
| *1 | Front Defroster | *2 | Side Defroster (LH) |
| *3 | Side Defroster (RH) | *4 | Mode Switching Damper (for Defroster) |
| *5 | Fresh/Recirculation | *6 | Clean Air Filter (Air Refiner Element) |
| *7 | Blower with Fan Motor Sub-assembly | *8 | No. 1 Cooler Evaporator |
| *9 | Air Mix Damper | *10 | Heater Radiator Unit Sub-assembly |
| *11 | Rear Mode Switching Damper | *12 | Mode Switching Damper (for Footwell Duct) |
| *13 | Mode Switching Damper (for Side Register) | *14 | Mode Switching Damper (for Center Register) |
| *15 | Rear Footwell Duct (LH) | *16 | Footwell Duct (RH) |
| *17 | Footwell Duct (RH) | *18 | Rear Footwell Duct (RH) |
| *19 | Rear Face Register Duct | *20 | Side Register (LH) |
| *21 | Center Register | *22 | Side Register (RH) |
| *a | Recirculated Air | *b | Fresh Air |
| *c | This illustration shows the dampers and air outlets schematically. Actual shapes and numbers of parts will differ from those shown in the illustration. | - | - |
MODE POSITION AND DAMPER OPERATION
| Damper | Operation Position | Damper Position | Operation |
|---|---|---|---|
| Air Inlet Control Damper | FRESH | A | Brings in fresh air. |
| RECIRCULATION | B | Recirculates internal air. | |
| Mode Control Damper | FACE | C, F, K, L | Blows air out of the center register and side register. |
| BI-LEVEL | C, G, J | Blows air out of the center register, side register and footwell register. | |
| FOOT | D, H, I, O | Blows air out of the footwell register duct. A small amount of air also blows out from the side register, front defroster and side defroster. | |
| FOOT/DEF | E, H, I, M | Defrosts the windshield through the front defroster and side defroster. At the same time, air is blown out from the footwell register. A small amount of air also blows out from the side register. | |
| DEF | E, H, I, L | Defrosts the windshield through the front defroster and side defroster. A small amount of air also blows out from the side register. |
AIR OUTLETS AND AIR FLOW VOLUME
Air Outlets and Airflow Volume
| Indication | Mode | Center Register | Side Register | Footwell Register and Rear Footwell Register*2 | Front Defroster, Side Defroster | Rear Face Register*1 |
|---|---|---|---|---|---|---|
| A | B | C, F | D | E | ||
|
FACE | |
|
- | - | |
|
BI-LEVEL | |
|
|
- | |
|
FOOT | - | |
|
|
- |
|
FOOT/DEF | - | |
|
|
- |
|
DEF | - | |
- | |
- |
*1: w/ Rear Face Register
*2: w/ Rear Footwell Register
The circle size (○) is proportional to the amount of air flow.