PROCEDURE
INSPECT UPPER ACCESS PANEL LOCK ASSEMBLY LH
| *a | Component without harness connected (Upper Access Panel Lock Assembly LH) |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the upper access panel lock assembly LH.
INSPECT UPPER ACCESS PANEL LOCK ASSEMBLY RH
| *a | Component without harness connected (Upper Access Panel Lock Assembly RH) |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the upper access panel lock assembly RH.
INSPECT LOWER ACCESS PANEL LOCK ASSEMBLY LH
| *a | Component without harness connected (Lower Access Panel Lock Assembly LH) |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the lower access panel lock assembly LH.
INSPECT LOWER ACCESS PANEL LOCK ASSEMBLY RH
| *a | Component without harness connected (Lower Access Panel Lock Assembly RH) |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the lower access panel lock assembly RH.