PROCEDURE
INSTALL GENERATOR ASSEMBLY
Install the generator assembly with the 2 bolts.
| 43 N*m | 438 kgf*cm | 32 ft.*lbf |
Connect the wire harness to terminal B with the nut.
| 9.8 N*m | 100 kgf*cm | 87 in.*lbf |
Install the generator bracket with the bolt.
| 13 N*m | 133 kgf*cm | 10 ft.*lbf |
Install the terminal cap.
Connect the generator connector.
INSTALL FAN AND GENERATOR V BELT
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY WITH NO. 1 AIR CLEANER HOSE
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.