Click here

GENERATOR(for 80A Type) REMOVAL

Click here
Click here Click here

PROCEDURE


  1. Click here

    PRECAUTION

    Note:

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

    Click here

  2. Click here

    DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. Click here

    REMOVE BATTERY CLAMP SUB-ASSEMBLY


    1. B0028V4

      Loosen the 2 nuts.

    2. Remove the 2 battery clamp bolts and battery clamp sub-assembly.

  4. Click here

    REMOVE BATTERY

  5. Click here

    REMOVE BATTERY TRAY

  6. Click here

    REMOVE NO. 4 AIR HOSE

    Click here

  7. Click here

    REMOVE FAN AND GENERATOR V BELT

    Click here

  8. Click here

    REMOVE GENERATOR ASSEMBLY


    1. B0024N7

      Disconnect the intake air temperature sensor connector.

    2. Disconnect the generator connector and detach the clamp.

    3. Remove the terminal cap.

    4. Remove the nut and disconnect the wire harness from terminal B.

    5. B00289N

      Detach the 3 clamps and disconnect the wire harness.

    6. B00274D

      Remove the 2 bolts and generator assembly.

    7. B0025WI

      Remove the 2 bolts and 2 generator brackets.