BACK-UP LIGHT SWITCH INSPECTION

PROCEDURE


  1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY


    1. A01LELDC01
      *a Pushed
      *b Released

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Switch Condition Specified Condition
      Pushed Below 1 Ω
      Released 10 kΩ or higher

      If the result is not as specified, replace the back-up light switch assembly.