COUNTER GEAR INSPECTION

PROCEDURE


  1. INSPECT COUNTER GEAR


    1. A01L9O7N01

      Using a micrometer, measure the outside diameter of the counter gear as shown in the illustration.

      Measuring point Standard outside diameter Minimum outside diameter
      A 29.984 to 30.000 mm (1.1805 to 1.1811 in.) 29.984 mm (1.1805 in.)

      If the outside diameter is less than the minimum, replace the counter gear.