BACK-UP LIGHT SWITCH INSTALLATION

PROCEDURE


  1. INSTALL BACK-UP LIGHT SWITCH ASSEMBLY


    1. A01L9VXN02

      Using SST, install a new gasket and the back-up light switch assembly.

      SST
      09817-16011
      Torque:
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }
    2. Connect the back-up light switch connector and attach the clamp.