PROCEDURE
INSPECT CLEARANCE BETWEEN VANE PUMP SHAFT AND BUSHING IN FRONT HOUSING
Using a micrometer, measure the diameter (a) of the shaft with pulley.
Using a caliper gauge, measure the inside diameter (b) of the front housing.
Note
Do not damage the bushing in the front housing.
Subtract (a) from (b) to calculate the oil clearance.
| Maximum clearance |
|---|
| 0.07 mm (0.00276 in.) |
If the clearance is more it is more than the maximum, replace the shaft with pulley.
INSPECT VANE PUMP ROTOR AND VANE PUMP PLATE
Using a feeler gauge, measure the clearance between the side face of the vane pump rotor groove and the vane pump plates.
| Maximum clearance |
|---|
| 0.025 mm (0.000984 in.) |
If the clearance is more than the maximum, replace the vane pump plates, vane pump rotor and vane pump cam ring.
Tech Tips
Refer to the following table to select an appropriate combination of vane pump rotor, vane pump cam ring and vane pump plates.
| Combination of Vane Pump Rotor, Vane Pump Cam Ring and Vane Pump Plates | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
INSPECT FLOW CONTROL VALVE
| *a | Compressed Air |
| *a | Mark |
Check the flow control valve for leakage. Close one of the holes and apply compressed air at 392 to 490 kPa (4.00 to 4.99 kgf/cm2, 56.9 to 71.0 psi) to the hole on the opposite side. Confirm that the air does not flow out of the end hole.
Note
Make sure to use clean and dry air.
If there is leakage, replace the flow control valve.
Tech Tips
Check the mark on the front housing and replace the flow control valve with one having the same mark as that of the front housing.
Refer to the following table to select an appropriate combination of front housing and flow control valve.
| Combination of Front Housing and Flow Control Valve | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Coat the flow control valve with power steering fluid.
Note
Make sure to use new power steering fluid.
Insert the flow control valve into the flow control valve installation hole of the front housing, and check that the flow control valve enters smoothly under its own weight.
If the flow control valve does not enter the front housing smoothly, replace the flow control valve.
INSPECT FLOW CONTROL VALVE COMPRESSION SPRING
Using a vernier caliper, measure the free length of the flow control valve compression spring.
| Minimum free length (A) (Reference) |
|---|
| 30.26 mm (1.19 in.) |
If the length is less than the minimum, replace the flow control valve compression spring.
INSPECT PRESSURE PORT UNION
If the union seat in the pressure port union is severely damaged, replace the pressure port union.