PROCEDURE
INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Check the No. 1 vacuum switching valve assembly for an open circuit.
| *a | Component without harness connected (No. 1 Vacuum Switching Valve Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
Check the operation of the No. 1 vacuum switching valve assembly.
Check that air does not flow from the port (E) to port (F) as shown in the illustration.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
Apply battery voltage between the terminals.
Check that air flows from the port (E) to port (F) as shown in the illustration.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.