PROCEDURE
INSTALL VACUUM RESERVOIR SUB-ASSEMBLY
Install the vacuum reservoir sub-assembly with the 3 bolts.
| 8.0 N*m | 82 kgf*cm | 71 in.*lbf |
Connect the suction hose sub-assembly to the vacuum reservoir sub-assembly with the bolt.
| 5.4 N*m | 55 kgf*cm | 48 in.*lbf |
CONNECT NO. 1 VACUUM HOSE CONNECTOR
Connect the No. 1 vacuum hose connector and slide the clip to secure it.
CONNECT UNION TO CHECK VALVE HOSE
Connect the union to check valve hose and slide the clip to secure it.