PROCEDURE
INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/ Smart Entry and Start System)
Tech Tips
If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.
Inspect wire harness (for LHD):
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Disconnect the shift lock control ECU connector from the transmission floor shift assembly.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Inspect wire harness (for RHD):
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Disconnect the shift lock control ECU connector from the transmission floor shift assembly.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Inspect shift lock solenoid:
| *a | Front view of wire harness connector (to Shift Lock Solenoid) |
Disconnect the shift lock solenoid connector from the shift lock control ECU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.
INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/o Smart Entry and Start System)
Tech Tips
If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.
Inspect wire harness (for LHD):
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Disconnect the shift lock control ECU connector from the transmission floor shift assembly.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Inspect wire harness (for RHD):
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Disconnect the shift lock control ECU connector from the transmission floor shift assembly.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Inspect shift lock solenoid:
| *a | Front view of wire harness connector (to Shift Lock Solenoid) |
Disconnect the shift lock solenoid connector from the shift lock control ECU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.
INSPECT TRANSMISSION CONTROL SWITCH
for LHD:
| *a | Component without harness connected (Transmission Control Switch) |
Disconnect the transmission control switch connector from the transmission floor shift assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
for RHD:
| *a | Component without harness connected (Transmission Control Switch) |
Disconnect the transmission control switch connector from the transmission floor shift assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.