PROCEDURE
INSPECT SHIFT SOLENOID VALVE SR
| *a | Component without harness connected (Shift Solenoid Valve SR) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve SR and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve SR.
INSPECT SHIFT SOLENOID VALVE SLU
| *a | Component without harness connected (Shift Solenoid Valve SLU) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve SLU and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve SLU.
INSPECT SHIFT SOLENOID VALVE SLT
Tech Tips
Refer to Inspect Shift Solenoid Valve SLU.
INSPECT SHIFT SOLENOID VALVE SL1
| *a | Component without harness connected (Shift Solenoid Valve SL1) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve SL1 and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve SL1.
INSPECT SHIFT SOLENOID VALVE SL2
Tech Tips
Refer to Inspect Shift Solenoid Valve SL1.
INSPECT SHIFT SOLENOID VALVE S1
| *a | Component without harness connected (Shift Solenoid Valve S1) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve.
INSPECT SHIFT SOLENOID VALVE S2
| *a | Component without harness connected (Shift Solenoid Valve S2) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve.