SPEED SENSOR INSPECTION

PROCEDURE


  1. INSPECT TRANSMISSION REVOLUTION SENSOR (NT)

    A01LF0GC67
    *a

    Component without harness connected

    (Transmission Revolution Sensor (NT))


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω

      If the result is not as specified, replace the transmission revolution sensor (NT).

  2. INSPECT TRANSMISSION REVOLUTION SENSOR (SP2)

    A01LF0GC67
    *a

    Component without harness connected

    (Transmission Revolution Sensor (SP2))


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω

      If the result is not as specified, replace the transmission revolution sensor (SP2).