PROCEDURE
INSTALL STARTER ASSEMBLY
Temporarily install the starter assembly and ground cable with the nut and 2 bolts.
Tighten bolt A and nut B.
| 68 N*m | 693 kgf*cm | 50 ft.*lbf |
Connect the starter wire with the nut.
| 9.8 N*m | 100 kgf*cm | 87 in.*lbf |
Connect the starter connector.
Install the starter terminal cap.
INSTALL STARTER STAY
Install the starter stay with the nut and 2 bolts.
| 12.3 N*m | 125 kgf*cm | 9 ft.*lbf |
INSTALL FRONT FENDER SEAL LH
Install the front fender seal LH with 6 new clips.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.