Click here

IGNITION SWITCH INSPECTION

Click here
Click here

PROCEDURE


  1. *a Component without harness connected (Ignition Switch Assembly)
    Click here

    INSPECT IGNITION SWITCH ASSEMBLY


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      - LOCK 10 kΩ or higher
      7 (ACC) - 5 (AM1) ACC Below 1 Ω

      8 (IG1) - 5 (AM1)

      7 (ACC) - 5 (AM1)

      4 (AM2) - 3 (IG2)

      ON Below 1 Ω

      8 (IG1) - 5 (AM1)

      6 (ST1) - 5 (AM1)

      4 (AM2) - 3 (IG2)

      4 (AM2) - 2 (ST2)

      START Below 1 Ω

      If the result is not as specified, replace the ignition switch assembly.