AUTOMATIC TRANSMISSION SYSTEM(for 2GD-FTV), Diagnostic DTC:P2759

DTC Code DTC Name
P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

DESCRIPTION

Refer to the system description for DTC P2757.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic).
  • Open or short in shift solenoid valve SLU circuit

  • Shift solenoid valve SLU

  • ECM

Comes on (w/ OBD)

- (w/o OBD)

DTC stored

MONITOR DESCRIPTION

When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines there is a malfunction. The ECM will illuminate the MIL* and store this DTC.

*: w/ OBD

WIRING DIAGRAM

B0027CWE58
*a Shift Solenoid Valve SLU
*b Transmission Wire

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transmission are replaced.

Click here

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Perform the Lock-up Function in Road Test.

    Click here

  2. Check for DTCs again.

    Click here

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)


    1. B0028EHC08
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      21 (SLU+) - 22 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      21 (SLU+) - Body ground Always 10 kΩ or higher
      22 (SLU-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. B0025FZC09
      *a

      Rear view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C58-8 (SLU+) - C58-9 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      C58-8 (SLU+) - Body ground Always 10 kΩ or higher
      C58-9 (SLU-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  3. INSPECT SHIFT SOLENOID VALVE SLU


    1. B0025VIC15
      *1 Shift Solenoid Valve SLU

      Remove shift solenoid valve SLU.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG