Click here

FUEL SENDER GAUGE ASSEMBLY INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT FUEL SENDER GAUGE ASSEMBLY


    1. Check the fuel sender gauge assembly output voltage.


      1. A01SABCC01
        *a

        Component without harness connected

        (Fuel Sender Gauge Assembly)

        *b Voltage applied between terminals

        Apply 5 V between terminals 1 (FV) and 2 (FE).

        Note:
        • Be careful when connecting the leads, as the fuel sender gauge assembly may be damaged if the leads are connected to the wrong terminals.

        • Do not apply more than 6 V to terminals 1 (FV) and 2 (FE).

        Tip:

        If a stable power supply is not available, use 4 1.2 V nickel-metal hydride batteries or equivalent.

      2. A01SANAC01
        *a

        Component without harness connected

        (Fuel Sender Gauge Assembly)

        Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        2 (FE) - 3 (FR) Float position is F (upper) 4.25 to 4.61 V*
        Float position is E (lower) 0.34 to 0.70 V*

        • *: The output voltage changes depending on the voltage applied to the terminals.

        Tip:
        • Output voltage (F) = (0.850 x Voltage applied to terminals) to (0.922 x Voltage applied to terminals)

        • Output voltage (E) = (0.068 x Voltage applied to terminals) to (0.140 x Voltage applied to terminals)

        If the result is not as specified, replace the fuel sender gauge assembly.