PROCEDURE
REMOVE FAN AND GENERATOR V BELT
Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the fan and generator V belt. Then remove the fan and generator V belt.
Note
When removing the fan and generator V belt, do not use the bolt of the idle pulley.
Tech Tips
After removing the fan and generator V belt, move the tensioner upward as far as possible.
REMOVE TENSIONER PULLEY
Note
Perform the following procedure when it is necessary to replace the tensioner pulley.
Remove the engine oil level dipstick.
Remove the bolt, engine oil level dipstick guide and O-ring.
Note
Cover the dipstick guide hole to prevent foreign matter from entering it.
Remove the bolt, dust seal and tensioner pulley.