DRIVE BELT REMOVAL

PROCEDURE


  1. REMOVE FAN AND GENERATOR V BELT


    1. A01LEDG

      Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the fan and generator V belt. Then remove the fan and generator V belt.

      Note

      When removing the fan and generator V belt, do not use the idle pulley's bolt.

      Tech Tips

      After removing the fan and generator V belt, move the tensioner upward as far as possible.

  2. REMOVE TENSIONER PULLEY

    Note

    Perform the following procedure when it is necessary to replace the tensioner pulley.


    1. Remove the engine oil level dipstick.

    2. Remove the bolt, engine oil level dipstick guide and O-ring.

      Note

      Cover the dipstick guide hole to prevent foreign matter from entering it.

    3. A01L9CM

      Remove the bolt, dust seal and tensioner pulley.