PROCEDURE
REMOVE NO. 1 AIR CLEANER HOSE
Disconnect the connector from the intake air temperature sensor.
Loosen the 2 clamps.
Remove the No. 1 air cleaner hose from the air cleaner cap sub-assembly and intake pipe.
REMOVE INTAKE PIPE
Remove the 2 bolts.
Loosen the hose clamp and remove the intake pipe from the intake flange.
REMOVE INTAKE FLANGE
Remove the bolt and disconnect the heater water hose from the intake flange.
Disconnect the connector from the manifold absolute pressure sensor.
Slide the clamp and disconnect the PCV hose from the intake flange.
Remove the 3 nuts, intake flange and gasket from the venturi assembly.
REMOVE VENTURI ASSEMBLY
Disconnect the 2 connectors from the venturi assembly.
Remove the venturi assembly and gasket from the intake manifold.