CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the body ECU removal/installation are shown below.
| Replacement Part or Procedure | Necessary Procedures | Effects/Inoperative when not Performed | Link |
|---|---|---|---|
| Replacement of body ECU | Initialize automatic light control system | Automatic light control system |
PROCEDURE
INSPECT EDU RELAY (EDU)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the EDU relay.
INSPECT IG2 RELAY (IG2)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the IG2 relay.
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) |
- | - |
Note
Before performing the relay inspections for the relays of the instrument panel junction block assembly, inspect the EFI-MAIN NO. 1, EFI-MAIN NO. 2 and EFI NO. 1 fuses.
Remove the instrument panel junction block assembly.
for LHD:
for RHD:
Remove the body ECU from the instrument panel junction block assembly.
for LHD:
for RHD:
Inspect the EFI-MAIN NO. 1 relay.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the instrument panel junction block assembly.
Inspect the EFI-MAIN NO. 2 relay.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the instrument panel junction block assembly.
Install the body ECU to the instrument panel junction block assembly.
for LHD:
for RHD:
Install the instrument panel junction block assembly.
for LHD:
for RHD: