SFI SYSTEM ACIS Control Circuit

DESCRIPTION

Refer to DTC P0660.

Click here

WIRING DIAGRAM

Refer to DTC P0660.

Click here

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. PERFORM ACTIVE TEST USING GTS (OPERATE VACUUM SWITCHING VALVE FOR ACIS)


    1. B0026C8C01
      *1 Air
      *2 Port F
      *3 Port E
      *4 Air Filter
      *a Vacuum Switching Valve Assembly is ON
      *b Vacuum Switching Valve Assembly is OFF

      Disconnect the vacuum hose from port F of the vacuum switching valve assembly (for acoustic control induction system).

    2. Connect the GTS to the DLC3.

    3. Start the engine.

    4. Enter the following menus: Powertrain / Engine and ECT / Active Test / Active the VSV for Intake Control.


      Powertrain > Engine > Active Test
      Tester Display
      Activate the VSV for Intake Control
    5. Operate the vacuum switching valve assembly for acoustic control induction system.

    6. Check the vacuum switching valve assembly air flow when switching the vacuum switching valve assembly.

      OK
      Test Condition Specified Condition
      Vacuum switching valve assembly is ON Air from port E flows out through port F
      Vacuum switching valve assembly is OFF Air from port E flows out through air filter
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK VACUUM HOSES (VACUUM SWITCHING VALVE (FOR ACIS) - INTAKE AIR CONTROL VALVE, INTAKE AIR SURGE TANK)


    1. Check the vacuum hoses.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT INTAKE AIR SURGE TANK (INTAKE AIR CONTROL VALVE)


    1. Inspect the intake air control valve (for ACIS).

      Click here

      Result
      Proceed to
      OK
      NG

    OK
    NG
  4. INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)


    1. Inspect the vacuum switching valve assembly (for ACIS).

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))


    1. B00275QC01
      *a

      Front view of wire harness connector

      (to Vacuum Switching Valve Assembly (for ACIS))

      Disconnect the vacuum switching valve assembly (for ACIS) connector.

    2. Turn the ignition switch to ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      C6-1 - Body ground Ignition switch ON 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) - ECM)


    1. Disconnect the vacuum switching valve assembly (for ACIS) connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C6-2 - C12-5 (ACIS) Always Below 1 Ω
      C6-2 or C12-5 (ACIS) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  7. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS))


    1. Disconnect the instrument panel junction block assembly connector.

    2. Disconnect the vacuum switching valve assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2N-1 - C6-1 Always Below 1 Ω
      2N-1 or C6-1 - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG