| Item | Specified Condition | ||
|---|---|---|---|
| w/o Viscous Heater | for Manual Transmission | w/o DPF | 8.6 liters (9.1 US qts, 7.6 Imp. qts) |
| w/ DPF | 8.7 liters (9.2 US qts, 7.7 Imp. qts) | ||
| for Automatic Transmission | w/o DPF | 9.1 liters (9.6 US qts, 8.0 Imp. qts) | |
| w/ DPF | 9.2 liters (9.7 US qts, 8.1 Imp. qts) | ||
| w/ Viscous Heater | for Automatic Transmission | w/ DPF | 9.6 liters (10.1 US qts, 8.4 Imp. qts) |
| Thermostat | Valve opening temperature | 80 to 84 °C (176 to 183 °F) |
| Valve lift | 10 mm (0.394 in.) or more at 95°C (203°F) |
| Reservoir cap | Standard Judgment Criterion | Standard value (for brand-new cap) |
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi) |
| Minimum standard value (for used cap) |
79 kPa (0.8 kgf/cm2, 11.4 psi) |