1KD-FTV INTAKE / EXHAUST SERVICE DATA

INTAKE SYSTEM
Turbocharger pressure Condition Specified Condition

Engine speed

(approximately 4600 rpm)

15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)

INTAKE MANIFOLD
Vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground
EXHAUST MANIFOLD w/ TURBOCHARGER
Axial play of turbine shaft Maximum axial play 0.11 mm (0.00433 in.)
Radial play of turbine shaft Maximum radial play 0.112 mm (0.00440 in.)
EXHAUST PIPE
Compression spring Minimum length 40 mm (1.57 in.)