BATTERY / CHARGING SERVICE DATA

Auxiliary Battery
Tester Connection Condition Specified Condition Result
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), power switch off 12.0 V or higher Auxiliary battery is OK
Below 12.0 V Recharge auxiliary battery
Recharge auxiliary battery - 5 A or less
DC/DC Converter
Item Tester Connection Condition Specified Condition
Current flowing from auxiliary battery Positive (+) auxiliary battery cable

Power switch on (READY)

(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)

Below 0 A or less

(no current from auxiliary battery)

Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 13.8 to 14.7 V
Thermistor Assembly
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ