| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal | 20°C (68°F), power switch off | 12.0 V or higher | Auxiliary battery is OK |
| Below 12.0 V | Recharge auxiliary battery | ||
| Recharge auxiliary battery | - | 5 A or less | |
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| Current flowing from auxiliary battery | Positive (+) auxiliary battery cable | Power switch on (READY) (The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.) |
Below 0 A or less (no current from auxiliary battery) |
| Auxiliary battery voltage | Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal | 13.8 to 14.7 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |