HYBRID / BATTERY CONTROL SERVICE DATA

Reserve Tank Cap
Standard value (for Brand-new cap)

94 to 123 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)

Minimum standard value (for Used Cap)

94 kPa (1.0 kgf/cm2, 13.6 psi)

Pump speed 1 pump per second
Relay
Item Tester Connection Condition Specified Condition
Ignition control relay (IGCT1 No. 1) 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω
EV Battery Junction Block(Check the SMRB)
Tester Connection Condition Specified Condition
(+) - 1 (CBI) 1 (SMRB) - 2 (GND) Auxiliary battery voltage not applied between terminals 10 kΩ or higher
1 (SMRB) - 2 (GND) Auxiliary battery voltage applied between terminals Below 1 Ω
1 (SMRB) - 2 (GND) -40 °to 80 °C (-104 to 176 °F) 25.0 to 59.0 Ω
EV Battery Junction Block(Check the SMRG)
Tester Connection Condition Specified Condition
(-) - 1 (CEI) 3 (SMRG) - 2 (GND) Auxiliary battery voltage not applied between terminals 10 kΩ or higher
3 (SMRG) - 2 (GND) Auxiliary battery voltage applied between terminals Below 1 Ω
3(SMRG) - 2(GND) -40 °to 80 °C (-104 to 176 °F) 25.0 to 59.0 Ω
EV Battery Junction Block(Check the SMRP)
Tester Connection Condition Specified Condition
(-) - 1 (CEI) 4 (SMRP) - 2 (GND) Auxiliary battery voltage not applied between terminals 10 kΩ or higher
4 (SMRP) - 2 (GND) Auxiliary battery voltage applied between terminals 28.5 to 31.5 Ω
4 (SMRP) - 2 (GND) -40 °to 80 °C (-104 to 176 °F) 112 to 274 Ω
Service Plug Grip (for EV)
Tester Connection Condition Specified Condition
Service plug grip (for EV) Always Below 1 Ω
Frame Wire
Tester Connection Condition Specified Condition
Frame wire connector housing - Body ground Always Below 1 Ω