| Standard value (for Brand-new cap) | 94 to 123 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum standard value (for Used Cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Pump speed | 1 pump per second |
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| Ignition control relay (IGCT1 No. 1) | 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| (+) - 1 (CBI) | 1 (SMRB) - 2 (GND) Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
| 1 (SMRB) - 2 (GND) Auxiliary battery voltage applied between terminals | Below 1 Ω | |
| 1 (SMRB) - 2 (GND) | -40 °to 80 °C (-104 to 176 °F) | 25.0 to 59.0 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| (-) - 1 (CEI) | 3 (SMRG) - 2 (GND) Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
| 3 (SMRG) - 2 (GND) Auxiliary battery voltage applied between terminals | Below 1 Ω | |
| 3(SMRG) - 2(GND) | -40 °to 80 °C (-104 to 176 °F) | 25.0 to 59.0 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| (-) - 1 (CEI) | 4 (SMRP) - 2 (GND) Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
| 4 (SMRP) - 2 (GND) Auxiliary battery voltage applied between terminals | 28.5 to 31.5 Ω | |
| 4 (SMRP) - 2 (GND) | -40 °to 80 °C (-104 to 176 °F) | 112 to 274 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Service plug grip (for EV) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Frame wire connector housing - Body ground | Always | Below 1 Ω |