AIR CONDITIONING SYSTEM(for Manual Cooler System) SYSTEM DESCRIPTION


  1. MODE POSITION AND DAMPER OPERATION

    B003PDRC01
    *1 Front Defroster *2 Side Defroster (LH)
    *3 Side Defroster (RH) *4 Mode Switching Damper (for Defroster)
    *5

    No. 1 Blower Damper Servo Sub-assembly


    • - Fresh/Recirculation

    *6 Clean Air Filter (Air Refiner Element)
    *7 Blower with Fan Motor Sub-assembly *8 No. 1 Cooler Evaporator
    *9 Mode Switching Damper (for Footwell Duct) *10 Mode Switching Damper (for Side Register)
    *11 Mode Switching Damper (for Center Register) *12 Footwell Duct (LH)
    *13 Footwell Duct (RH) *14 Side Register (LH)
    *15 Center Register *16 Side Register (RH)
    *a Recirculated Air *b Fresh Air
    *c This illustration shows the dampers and air outlets schematically. Shapes and numbers of parts shown in the illustration will differ from the actual. - -
    Mode Position and Damper Operation Chart
    Damper Operation Position Damper Position Operation
    Air Inlet Control Damper FRESH A Brings in fresh air.
    RECIRC B Recirculates internal air.
    Mode Control Damper FACE C, F, K, L Air blows out of the center register and side register.
    BI-LEVEL C, G, J, N Air blows out of the center register, side register and footwell register.
    FOOT D, H, I, O Air blows out of the footwell register duct. A small amount of air also blows out from the side register, front defroster and side defroster.
    FOOT/DEF E, H, I, M Defrosts the windshield through the front defroster and side defroster. At the same time, air is blown out from the footwell register. A small amount of air also blows out from the side register.
    DEF E, H, I, L Defrosts the windshield through the front defroster and side defroster. A small amount of air also blows out from the side register.
  2. AIR OUTLETS AND AIR FLOW VOLUME

    B003SB4
    Indication Mode Center Register Side Register Footwell Duct Front Defroster, Side Defroster
    A B C D
    B003QIK FACE B003JXK B003JXK - -
    B003K43 BI-LEVEL B003JAM B003JAM B003JAM -
    B003RQ1 FOOT - B003N4Y B003JXK B003N4Y
    B003PRY FOOT/DEF - B003N4Y B003JAM B003JAM
    B003MQ3 DEF - B003N4Y - B003JXK

    Tech Tips