DESCRIPTION
The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.
WIRING DIAGRAM
| *a | from Battery |
| *b | Blower Motor Control |
| *c | Air Conditioning Amplifier Assembly |
| *d | Blower with Fan Motor Sub-assembly |
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
When the servo motor or air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
PROCEDURE
PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0 Max.: 31 |
- |
| Tester Display |
|---|
| Blower Motor |
| OK |
|---|
| Blower with fan motor sub-assembly operates and changes speed. |
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY
Remove the blower with fan motor sub-assembly.
Inspect the blower with fan motor sub-assembly.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BATTERY AND BODY GROUND)
| *a | Front view of wire harness connector (to Blower Motor Control) |
Disconnect the blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the G35 blower motor control connector.
Disconnect the G37 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BLOWER MOTOR CONTROL AND BODY GROUND)
Disconnect the G6 blower with fan motor sub-assembly connector.
Disconnect the G35 blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
| *a | Component with harness connected (Blower Motor Control) |
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G35-3 (SI) - Body ground |
| Tool Setting | 2 V/DIV., 500 μs/DIV. |
| Condition |
|
| OK |
|---|
| Waveform is as shown in the illustration. |
Tech Tips
Waveform varies with the blower level.
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE BLOWER MOTOR CONTROL Click here |
| NG |
|
CHECK BLOWER MOTOR CONTROL
Replace the blower motor control.
Check if the same malfunction recurs when the sonar function is operated.
| OK |
|---|
| Malfunction does not reoccur (returns to normal). |
| Result | |||
|---|---|---|---|
|
| OK |
|
END (BLOWER MOTOR CONTROL IS DEFECTIVE) |
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |