POWER SEAT SWITCH INSPECTION

PROCEDURE


  1. INSPECT FRONT POWER SEAT SWITCH RH (for RHD)


    1. B003S5ZC01
      *1 Slide Switch
      *2 Front Vertical Switch
      *3 Lifter Switch
      *4 Reclining Switch
      *a

      Component without harness connected

      (Front Power Seat Switch RH)

      Measure the resistance according to the value (s) in the tables below.

      Standard Resistance (Slide Switch):
      Tester Connection Switch Condition Specified Condition
      2 (SLDF) - 13 (B) Front position Below 1 Ω
      5 (SLDR) - 10 (E)
      2 (SLDF) - 10 (E) Neutral Below 1 Ω
      5 (SLDR) - 10 (E)
      2 (SLDF) - 10 (E) Rear position Below 1 Ω
      5 (SLDR) - 13 (B)
      Standard Resistance (Front Vertical Switch):
      Tester Connection Switch Condition Specified Condition
      6 (FUP) - 13 (B) Up position Below 1 Ω
      1 (FDWN) - 10 (E)
      6 (FUP) - 10 (E) Neutral Below 1 Ω
      1 (FDWN) - 10 (E)
      6 (FUP) - 10 (E) Down position Below 1 Ω
      1 (FDWN) - 13 (B)
      Standard Resistance (Lifter Switch):
      Tester Connection Switch Condition Specified Condition
      4 (LUP) - 13 (B) Up position Below 1 Ω
      3 (LDWN) - 10 (E)
      4 (LUP) - 10 (E) Neutral Below 1 Ω
      3 (LDWN) - 10 (E)
      4 (LUP) - 10 (E) Down position Below 1 Ω
      3 (LDWN) - 13 (B)
      Standard Resistance (Reclining Switch):
      Tester Connection Switch Condition Specified Condition
      11 (RCLF) - 13 (B) Front position Below 1 Ω
      12 (RCLR) - 10 (E)
      6 (FUP) - 13 (B)
      1 (FDWN) - 13 (B)
      11 (RCLF) - 10 (E) Neutral Below 1 Ω
      12 (RCLR) - 10 (E)
      11 (RCLF) - 10 (E) Rear position Below 1 Ω
      12 (RCLR) - 13 (B)
      3 (LDWN) - 13 (B)
      4 (LUP) - 13 (B)

      If the result is not as specified, replace the front power seat switch RH.

  2. INSTALL FRONT POWER SEAT SWITCH LH (for LHD)


    1. B003RXVC17
      *1 Slide Switch
      *2 Front Vertical Switch
      *3 Lifter Switch
      *4 Reclining Switch
      *a

      Component without harness connected

      (Front Power Seat Switch LH)

      Measure the resistance according to the value (s) in the tables below.

      Standard Resistance (Slide Switch):
      Tester Connection Switch Condition Specified Condition
      5 (SLDF) - 8 (B) Front position Below 1 Ω
      2 (SLDR) - 11 (E)
      5 (SLDF) - 11 (E) Neutral Below 1 Ω
      2 (SLDR) - 11 (E)
      5 (SLDF) - 11 (E) Rear position Below 1 Ω
      2 (SLDR) - 8 (B)
      Standard Resistance (Front Vertical Switch):
      Tester Connection Switch Condition Specified Condition
      1 (FUP) - 8 (B) Up position Below 1 Ω
      6 (FDWN) - 11 (E)
      1 (FUP) - 11 (E) Neutral Below 1 Ω
      6 (FDWN) - 11 (E)
      1 (FUP) - 11 (E) Down position Below 1 Ω
      6 (FDWN) - 8 (B)
      Standard Resistance (Lifter Switch):
      Tester Connection Switch Condition Specified Condition
      3 (LUP) - 8 (B) Up position Below 1 Ω
      4 (LDWN) - 11 (E)
      3 (LUP) - 11 (E) Neutral Below 1 Ω
      4 (LDWN) - 11 (E)
      3 (LUP) - 11 (E) Down position Below 1 Ω
      4 (LDWN) - 8 (B)
      Standard Resistance (Reclining Switch):
      Tester Connection Switch Condition Specified Condition
      10 (RCLF) - 8 (B) Front position Below 1 Ω
      9 (RCLR) - 11 (E)
      1 (FUP) - 8 (B)
      6 (FDWN) - 8 (B)
      10 (RCLF) - 11 (E) Neutral Below 1 Ω
      9 (RCLR) - 11 (E)
      10 (RCLF) - 11 (E) Rear position Below 1 Ω
      9 (RCLR) - 8 (B)
      4 (LDWN) - 8 (B)
      3 (LUP) - 8 (B)

      If the result is not as specified, replace the front power seat switch LH.