DOOR CONTROL BATTERY INSPECTION

PROCEDURE


  1. INSPECT DOOR CONTROL BATTERY


    1. B003M8MC09
      *a

      Component without harness connected

      (Door Control Battery)

      Inspect the door control battery.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        5 (BATB) - 11 (DRLY) Voltage is not applied between terminals 8 (IG) and 9 (ACTG) Below 1 Ω
        Voltage is applied between terminals 8 (IG) and 9 (ACTG) 10 kΩ or higher

        If the result is not as specified, replace the door control battery.

      2. Measure the voltage according to the value(s) in the table below.

        Tester Connection Condition Specified Condition
        11(DRLY) - Battery negative (-)

        Battery positive (+) - 8 (IG)

        Battery negative (-) - 9 (ACTG)

        11 to 14 V
        3 (EDOR) - Battery negative (-)

        If the result is not as specified, replace the door control battery.