GENERATOR(for 100A Type) REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE AIR CLEANER CAP SUB-ASSEMBLY WITH NO. 1 AIR CLEANER HOSE

    Click here

  4. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

    Click here

  5. REMOVE AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  6. REMOVE FAN AND GENERATOR V BELT

    Click here

  7. REMOVE GENERATOR ASSEMBLY

    B003LCT

    1. Disconnect the generator connector.

    2. Remove the terminal cap.

    3. Remove the bolt and generator bracket.

    4. Remove the nut and disconnect the wire harness from terminal B.

    5. Remove the 3 bolts and generator assembly.