GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE BATTERY CLAMP SUB-ASSEMBLY


    1. B003L0K

      Loosen the 2 nuts.

    2. Remove the 2 battery clamp bolts and battery clamp sub-assembly.

  4. REMOVE BATTERY

  5. REMOVE BATTERY TRAY

  6. REMOVE NO. 4 AIR HOSE

    Click here

  7. REMOVE FAN AND GENERATOR V BELT

    Click here

  8. REMOVE GENERATOR ASSEMBLY


    1. B003R8Y

      Disconnect the intake air temperature sensor connector.

    2. Disconnect the generator connector and detach the clamp.

    3. Remove the terminal cap.

    4. Remove the nut and disconnect the wire harness from terminal B.

    5. B003LLR

      Detach the 3 clamps and disconnect the wire harness.

    6. B003LD6

      Remove the 2 bolts and generator assembly.

    7. B003JSJ

      Remove the 2 bolts and 2 generator brackets.