GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE AIR CLEANER CAP SUB-ASSEMBLY WITH AIR CLEANER HOSE

    Click here

  4. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

    Click here

  5. REMOVE AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  6. REMOVE FAN AND GENERATOR V BELT

    Click here

  7. REMOVE NO. 2 IDLER PULLEY ASSEMBLY

    B003MJB

    1. Remove the bolt, 2 pulley plates, No. 2 idler pulley assembly and spacer.

  8. REMOVE GENERATOR ASSEMBLY

    B003MVJ

    1. Remove the nut and generator wire from terminal B.

    2. Disconnect the generator connector.

    3. Remove the 2 bolts and generator assembly.