AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR REMOVAL

PROCEDURE


  1. REMOVE NO. 1 ENGINE UNDER COVER

    Click here

  2. REMOVE NO. 2 ENGINE UNDER COVER

    Click here

  3. DRAIN DIFFERENTIAL OIL

    Click here

  4. REMOVE DIFFERENTIAL MOTOR ACTUATOR ASSEMBLY


    1. B003JHY

      Disconnect the breather hose from the differential breather tube bracket.

    2. B003REI

      Remove the bolt and disconnect the differential breather tube bracket.

    3. B003OID

      Disconnect the differential breather hose from the front differential union.

    4. B003MLI

      Disconnect the differential oil temperature sensor connector.

    5. Remove the bolt and disconnect the bracket.

    6. B003J58

      Disconnect the differential motor actuator connector.

    7. Remove the bolt and disconnect the bracket.

    8. B003PMBC03
      *1 Mounting Bolt
      *2 Mounting Nut

      Support the differential with a jack.

    9. Remove the No. 1 differential mounting nut.

    10. Remove the 2 mounting bolts and 2 nuts.

    11. Lower the jack.

    12. B003Q70

      Remove the 4 bolts.

    13. B003NKV

      Using a hammer, pry out the differential motor actuator assembly from the differential tube.