PROCEDURE
INSPECT COUNTER GEAR
Using a micrometer, measure the outside diameter of the counter gear as shown in the illustration.
| Measuring point | Standard outside diameter | Minimum outside diameter |
|---|---|---|
| A | 29.984 to 30.000 mm (1.1805 to 1.1811 in.) | 29.984 mm (1.1805 in.) |
If the outside diameter is less than the minimum, replace the counter gear.