AUTOMATIC TRANSMISSION SYSTEM, Diagnostic DTC:P0985, P0986

DTC Code DTC Name
P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)
P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)

DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2 and SR, which are controlled by the TCM. If an open or short circuit occurs in one of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In the case of an open or short circuit, the TCM stops sending current to the circuit. For details, refer to the fail-safe chart.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR) TCM detects a short in the shift solenoid valve SR circuit 2 times when shift solenoid valve SR is operated (1-trip detection logic).
  • Short in shift solenoid valve SR circuit

  • Shift solenoid valve SR

  • TCM

Comes on DTC stored
P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR) TCM detects an open in the shift solenoid valve SR circuit 2 times when shift solenoid valve SR is not operated (1-trip detection logic).
  • Open in shift solenoid valve SR circuit

  • Shift solenoid valve SR

  • TCM

Comes on DTC stored

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve SR is on, if its resistance is 8 Ω or less, the TCM determines there is a short in the shift solenoid valve SR circuit.

When shift solenoid valve SR is off, if its resistance is 100 kΩ or higher, the TCM determines there is an open in the shift solenoid valve SR circuit.

Click here

WIRING DIAGRAM

B003P4CE67
*1 Shift Solenoid Valve SR
*2 Transmission Wire

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transmission are replaced.

Click here

Tech Tips


  • Shift solenoid valve SR is turned ON/OFF normally when the shift lever is in D.

    TCM gear shift command 1st 2nd 3rd 4th 5th
    Shift solenoid valve SR OFF OFF OFF OFF ON
  • After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


    1. Perform the D Position Shift Test in Road Test.

      Click here

    2. Check for DTCs again.

      Click here

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)


    1. B003OJMC54
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 (SR) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    1. B003S8BC34
      *a

      Rear view of wire harness connector

      (to TCM)

      Disconnect the TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C116-16 (SR) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  3. INSPECT SHIFT SOLENOID VALVE SR


    1. B003K0SC06
      *a

      Component without harness connected

      (Shift Solenoid Valve SR)

      Remove shift solenoid valve SR.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve SR connector

      • Battery negative (-) → Shift solenoid valve SR body

      Valve moves and makes an operating noise
      Result
      Proceed to
      OK
      NG

    OK
    NG