AIR INJECTION DRIVER(w/ Secondary Air Injection System) INSTALLATION

PROCEDURE


  1. INSTALL AIR INJECTION CONTROL DRIVER


    1. Install the air injection control driver to the air injection control bracket with the 2 screws.

      Torque:
      2.0 N*m  { 20 kgf*cm, 18 in.*lbf }
  2. INSTALL AIR INJECTION CONTROL DRIVER WITH BRACKET


    1. Install the air injection control driver with bracket with the 2 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. Connect the body ground to the bracket with the bolt.

      Torque:
      8.3 N*m  { 85 kgf*cm, 73 in.*lbf }
    3. Attach the wire harness clamp.

    4. Connect the 2 air injection control driver connectors.