PROCEDURE
INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
| *a | Component without harness connected (No. 1 vacuum switching valve assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
Check operation of the No. 1 vacuum switching valve assembly.
| *a | Vacuum |
| *b | Air |
| *c | Port E |
| *d | Port F |
| *e | Filter |
When a vacuum of 60 kPa (450 mmHg, 18 in.Hg) is applied to port F, check that air flows from port E to the filter.
| *a | Air |
| *b | Port F |
| *c | Port E |
Apply battery voltage 12V across terminals 1 and 2.
Check that air flows from port E to port F.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.